TM 10-3930-675-10
0013 00-13
Table 1. Preventive Maintenance Checks and
Services (PMCS) for RTCH-RT 240 - Continued.
ITEM
NO.
INTERVAL
LOCATION
PROCEDURE
NOT FULLY MISSION
CAPABLE IF:
ITEM TO
CHECK/
SERVICE
41
After
Twistlocks
Visually check all twistlocks, hydrau-
lic cylinders, electrical wiring, and
switches for signs of damage.
Damage that would impair
operation is evident. Class III
leaks are evident.
NOTE
Perform the following checks if forklift kit was used.
42
After
Forklift Kit
a. Check for damage or leaks to lines,
fittings, and hydraulic cylinders.
a. Class III leaks are evident.
b. Check for cracks or other damage to
forks.
c. Inspect fork positioning shaft for
dirt or damage.
43
Weekly
Air Cleaner
Assembly
WARNING
If NBC exposure is suspected, all air cleaner media should be
handled by personnel wearing protective equipment. Consult
your NBC officer or NBC NCO for appropriate handling or
disposal procedures.
Remove cover and service air cleaner
assembly as required (WP 0014 00).
HYDRAULIC
LINES
HYDRAULIC
CYLINDER
COVER
TWISTLOCK
SWITCH
TWISTLOCK