TM 10-3930-675-100013 00-15Table 1. Preventive Maintenance Checks andServices (PMCS) for RTCH-RT 240 - Continued.ITEM NO.INTERVALLOCATIONPROCEDURENOT FULLY MISSIONCAPABLE IF:ITEM TOCHECK/SERVICE46 (Con’t)WeeklyFuel/WaterSeparatorTurn drain knob counterclockwise anddrain all water from fuel/water separa-tor. Turn knob clockwise to close.46WeeklyEther Quick-Start SystemWARNINGEther is highly flammable and explosive. DO NOT performether quick-start system checks or inspections while smokingor near fire, flame or sparks. Failure to follow this warningmay cause a fire or explosion, causing serious injury or deathto personnel.Check for loose connections and dam-age to lines, fittings, and canister. Bealert for odor of leaking ether. Damage is noted.FUEL/WATERSEPARATORDRAINKNOB