TM 10-3930-675-100014 00-2ENGINE AIR CLEANER SERVICING - CONTINUED0014 004.Clean inside of housing with a clean, damp rag.WARNINGCompressed air used for cleaning purposes should never exceed 30 psi (207 kPa). Wear protective clothing(goggles/shield, gloves, etc.) and use caution to avoid injury to personnel.5.Use compressed air, directed from the outside (clean air side) toward the inside, to remove dust and dirt from primary andsecondary filter elements.6.After cleaning with compressed air, inspect primary and secondary filter elements for tears or other damage. Replace withnew filter elements, if damaged.7.Install secondary filter element and seat inside housing. Install primary filter element.8.Install cover on housing and secure with six latches.9.Reset air cleaner restriction indicator.