TM 10-3930-675-10
0005 00-12
OPERATION UNDER USUAL CONDITIONS - CONTINUED
0005 00
OPERATE LIFTING BOOM AND TOPHANDLER - CONTINUED
(4) Press left button and multiple function trigger button to close tophandler from 40 to 20 ft or to close forklift tines,
if forklift kit is installed.
e.
Twistlock Lock/Unlock Button.
NOTE
When twistlocks are locked, GREEN indicator light on steering column inside cab and at end of boom will illu-
minate. Three IR lights at end of boom also illuminate, when operating in blackout mode.
When twistlocks are unlocked, RED indicator light on steering column inside cab and at end of boom will illu-
minate. Single IR light at end of boom also illuminates, when operating in blackout mode.
Pressing twistlock lock/unlock button and override switch at the same time will lock out or disable boom lifting
and lowering operation; twistlock indicator light will turn off. To reactivate boom, momentarily press twistlock
lock/unlock button and override switch at the same time.
(1) Press button to lock twistlocks, securing load.
(2) Press button to unlock twistlocks, releasing load.