TM 10-3930-675-10
0005 00-25
OPERATION UNDER USUAL CONDITIONS - CONTINUED
0005 00
OPERATE PORTABLE FIRE EXTINGUISHER
WARNING
Discharging large quantities of dry chemical fire extinguisher in cab may result in temporary breathing diffi-
culty during and immediately after the discharge event. If at all possible, discharge fire extinguisher from
outside the cab. Ventilate cab thoroughly prior to reentry.
NOTE
This is a type B or C fire extinguisher. Use on oil and electrical fires only.
1.
Remove fire extinguisher from bracket located to the right rear of the operators seat.
2.
Hold fire extinguisher upright. Point nozzle toward base of fire and pull safety pin.
3.
Squeeze lever, discharging chemical at base of fire. Use a side-to-side motion to spread the chemical.
4.
After using fire extinguisher, notify Organizational Maintenance.
FORKLIFT KIT INSTALLATION
1.
General.
a.
The forklift kit attaches to the tophandler twistlocks and hydraulic system. The forklift is attached with the kit in a
folded configuration.
b.
The procedure requires two personnel: one person in the cab operating the joystick controls; one person installing/
removing retaining pins, connecting the hydraulic quick disconnect hoses, and ground guiding the operator.
2.
Installing Forklift Kit.
a.
Position tophandler directly over and level with forklift kit.
b.
Lower tophandler onto forklift kit and secure with twistlocks.
TOPHANDLER
FORKLIFT KIT