OVERLOAD PROTECTION TROUBLESHOOTING - CONTINUED
0010 00
Table 8. Error Code 210 - Tophandler Angle Sensor or Circuit Failure Troubleshooting Procedures
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Error Code 210 - Tophandler Angle Sensor or
Circuit Failure
1. Inspect
tophandler
angle
sensor and lever and bracket
for
damage
and
secure
mounting.
2. Remove
cover
from
tophandler
junction
box
located on right side of boom
and check voltage between
connector X180 pin 10 and
pin 12. Voltage should be
10V.
If voltage is present, check
voltage between connector
X180 pin 10 and pin 11.
Voltage should be 0.3-9.5V
depending on position of
boom.
If voltage is not present, replace
tophandler angle sensor (WP
0100 00).
3. Remove ECU (790) cover
from operators seat base and
slide ECU mounting tray out
(WP 0079 00).
4. Check ECU (790) connector
1, connector X159, and ECU
tray grounding leads for
proper connection.
a. Connect
any
loose
or
disconnected
connections.
Push ECU mounting tray in
and install cover.
b. Repair
or
replace
any
damaged connectors (WP
0111
00).
Push
ECU
mounting tray in and install
cover.
5. Enter
DIAG
ATTACH-
MENT 1 (16) menu and
check voltage of 10V REF
OUT. Voltage should be 10V.
a. If voltage is not as specified,
replace ECU (790) (WP 0079
00).
b. If voltage is as specified,
notify SRA.
DIAG TOP LIFT 1(16)
SYSTEM POWER 24.00V
POWER RI CAN 24.00V
POWER LE CAN 24.00V
10 V REF OUT 10.00V