TM 10-3930-675-20-10012 00-4ELECTRONIC CONTROL UNIT (ECU) INPUT VOLTAGE TROUBLESHOOTING - CONTINUED0012 00NOTEECU (790) has detected a 10V reference voltage out of range (9.3-10.4V).Table 3. Error Code 123 - 10V Reference Voltage for Servo ECU (790) Failure Troubleshooting Procedures.MALFUNCTIONTEST OR INSPECTIONCORRECTIVE ACTIONError Code 123 - 10V Reference Voltage forServo ECU (790) Failure1. Ensure that emergency stopswitch is not activated.Release emergency stop switchas required (TM 10-3930-675-10).2. Remove cab circuit breakerpanel cover and ensure thatcircuit breakers F30 and F32are not tripped.Reset circuit breakers asrequired (WP 0073 00).3. Remove servo ECU (790)cover from operator’s seatbase and slide ECU mountingtray out (WP 0079 00).4. Disconnect ECU (790) con-nectors X155 and X157.5. Enter “DIAG SERVO 1 (13)”menu and check voltage of10V REF OUT. Voltageshould be 9.3-10.4V.a. If voltage is correct,connect connector X155and continue withtroubleshooting pro-cedure.b. If voltage is not asspecified, check continuitybetween servo ECU (790)connector 1 in 26 andconnector X155 pin 13 andbetween servo ECU (790)connector 1 pin 27 andconnector X155 pin 12.a. If continuity is present,replace servo ECU (790)(WP 0079 00).b. If continuity is not present,notify SRA.DIAG SERVO1(13)SYSTEM POWER24.00VPOWER RI CAN24.00VPOWER LE CAN24.00V10V REF OUT10.00V