TM 10-3930-675-20-1
0023 00-12
ENGINE FUEL PRESSURE SENSORS AND CIRCUITS TROUBLESHOOTING - CONTINUED
0023 00
Table 3. Error Code 1582 - Fuel Inlet Restriction Sensor Circuit Failure Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Error Code 1582 - Fuel Inlet Restriction Sensor
Circuit Failure - Continued
7. Place ignition switch to OFF
position, disconnect actuator
harness
connector
from
engine ECU, and disconnect
fuel inlet restriction sensor
from engine harness.
a. Mesure
resistance
from
actuator harness connector
pin 28 to engine block
ground. Resistance should
be greater than 100k ohms.
If voltage is not as specified,
notify SRA to replace engine
harness.
b. Mesure
resistance
from
actuator harness connector
pin 29 to engine block
ground. Resistance should
be greater than 100k ohms.
If voltage is not as specified,
notify SRA to replace engine
harness.
>100K