TM 10-3930-675-20-1
0027 00-6
TRANSMISSION SPEED SENSORS TROUBLESHOOTING - CONTINUED
0027 00
ERROR CODE 653 - TURBINE SPEED SENSOR FAILURE, SHORT CIRCUIT TO CHASSIS - CONTINUED
Table 5. Error Code 653 - Turbine Speed Sensor Failure, Short Circuit to Chassis
Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Error Code 653 - Turbine Speed Sensor Failure,
Short Circuit to Chassis - Continued
5. Disconnect connector 751,
connector
X173,
and
connector on transmission
ECU.
6. Check for
continuity
to
chassis at connector 751 pin 7,
connector
X173
pin
6,
connector 751 pin 8, and
connector X173 pin 7.
a. If continuity is present, repair
or replace connectors (WP
0111 00).
b. If wiring harness must be
replaced, notify SRA.
7. Perform internal
resistance
check on turbine speed sensor.
Resistance should be 1050 +/-
100 ohms.
If
resistance
is not as specified,
replace turbine speed sensor (WP
0095 00).
8. Perform
continuity
check
between turbine speed sensor
pin 1 and pin 2 and chassis.
If continuity is present, replace
turbine speed sensor (WP 0095
00).
Table 6. Error Code 654 - Turbine Speed Sensor Failure, Logical Error Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Error Code 654 - Turbine Speed Sensor Failure,
Logical Error
Place ignition switch in OFF
position for 30 seconds and then
back in ON position.
If error code is still present,
perform troubleshooting pro-
cedures for error code 652.