TM 10-3930-675-20-1
0037 00-1
AUXILIARY PUMP TROUBLESHOOTING
0037 00
THIS WORK PACKAGE COVERS
Error Code 169 - Tophandler Emergency Function Sup-
ply Valve, Open or Short Circuit Failure
Error Code 411 - Auxiliary Pump, Control Current Short
Circuit Failure
Error Code 417 - Auxiliary Pump, Input from Switch
Failure
INITIAL SETUP
References
TM 10-3930-675-10
Current Supply (A34738.0200) (WP 0199 00-31)
ECS Electrical Servo (A34648.0200) (WP 0199 00-5)
Auxiliary Pump (A34746.0200) (WP 0199 00-47)
NOTE
Refer to WP 0004 00 for additional troubleshooting guidance, information, and illustrations
that locate critical components.
Refer also to illustration at end of work package for component location.
Table 1. Error Code 169 - Tophandler Emergency Function Supply Valve, Open or Short Circuit Failure
Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Error Code 169 - Tophandler Emergency
Function Supply Valve, Open or Short Circuit
Failure
1. Remove ECU (790) cover
from operators seat base and
slide ECU mounting tray out
(WP 0079 00).
2. Check ECU (790) connector
2 and tray grounding leads for
proper connections.
a. Connect
any
loose
or
disconnected
connections.
Push ECU mounting tray in
and install cover.
b. Repair or replace damaged
connectors (WP 0111 00).
Push ECU mounting tray in
and install cover.
3. Disconnect electrical con-
nector
from
tophandler
supply valve solenoid 6041,
located under cab on frame
rail, and perform voltage
check.
a. If 20-25V is present at
connector
6041,
replace
tophandler
supply
valve
solenoid (WP 0169 00).
b. If no voltage is present,
continue troubleshooting.
DIAG SERVO
12(13)
VALVES OUTPUT/INPUT
ATTACH. 0.00V 0mA
PUMP OFF 0.00V 0mA