TM 10-3930-675-20-1
0037 00-3
AUXILIARY PUMP TROUBLESHOOTING - CONTINUED
0037 00
Table 2. Error Code 411 - Auxiliary Pump, Control Current Short Circuit Failure
Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Error Code 411 - Auxiliary Pump, Control
Current Short Circuit Failure
Check
continuity
between
connector X174 pin 5 and
connector X46 pin 9 and
connector XK3 pin 8 and pin 5.
a. If continuity between pins,
repair or replace connectors
(WP 0111 00).
b. If
continuity
(short)
to
chassis, repair or replace
connectors (WP 0111 00).
c. If continuity is present, notify
SRA.
Table 3. Error Code 417 - Auxiliary Pump, Input from Switch Failure Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Error Code 417 - Auxiliary Pump, Input from
Switch Failure
Check
continuity
between
connector X174 pin 4 and
connector X47 pin 4 and
connector X67 pin 2 and
emergency pump switch 122 pin
1.
a. If continuity between pins,
repair or replace connectors
(WP 0111 00).
b. If
continuity
(short)
to
chassis, repair or replace
connectors (WP 0111 00).
c. If continuity is present, notify
SRA.