TM 10-3930-675-20-1
0045 00-1
TOPHANDLER SIDESHIFT TROUBLESHOOTING
0045 00
THIS WORK PACKAGE COVERS
Error Code 225 - Tophandler Sideshift Left, Open Cir-
cuit Failure
Error Code 226 - Tophandler Sideshift Left, Short Cir-
cuit Failure
Error Code 228 - Tophandler Sideshift Right, Open Cir-
cuit Failure
Error Code 229 - Tophandler Sideshift Right, Short Cir-
cuit Failure
INITIAL SETUP
References
TM 10-3930-675-10
ECS Attachment (A34652.0200) (WP 0199 00-23)
NOTE
Refer to WP 0004 00 for additional troubleshooting guidance, information, and illustrations
that locate critical components.
Refer also to illustration at end of work package for component location.
Table 1. Error Code 225 - Tophandler Sideshift Left, Open Circuit Failure Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Error Code 225 - Tophandler Sideshift Left,
Open Circuit Failure
1. Check wires and cables from
tophandler control valve to
boom for obvious damage.
Repair or replace damaged wires
(WP 0111 00).
2. Disconnect
electrical
connector
6020
from
tophandler
sideshift
left
solenoid.
Place
ignition
switch to ON position and
perform voltage check at pins
1 and 2.
If 20-25V is present at connector
6020, replace sideshift left
solenoid (WP 0169 00).
3. Disconnect connector X189
from tophandler junction box
at end of boom. Place ignition
switch to ON position and
perform
voltage
check
between connector X189 pin
A and pin B.
DIAG TOP LIFT 7(16)
SIDE SH.OUTPUT/INPUT
LEFT 0.00mV 0mA
RIGHT 0.00mV 0mA