TM 10-3930-675-20-10044 00-9TOPHANDLER LEVELING TROUBLESHOOTING - CONTINUED0044 00Table 7. Error Code 271 - Tophandler Leveling Left, Short Circuit Failure Troubleshooting Procedures - Continued.MALFUNCTIONTEST OR INSPECTIONCORRECTIVE ACTIONError Code 271 - Tophandler Leveling Left,Short Circuit Failure - Continued3. Disconnect connector X189from tophandler junction boxat end of boom. Place ignitionswitch to OFF position andcheck continuity betweenconnector 6036 pin 1 andpin 2 and between connector6036 pin 1 and pin 2 andchassis.a. If continuity is not present,repair or replace connectors(WP 0111 00). b. If wiring harness requiresreplacement, notify DSMaintenance.4. Enter “DIAG ATTACH-MENT 14 (16)” menu andcheck current ofOSCILLATION, LEFTOUTPUT. Current should bepresent with joystick levelingright activated.a. If current is not present,replace ECU (791) (WP 007600).b. If current is present, notifySRA.