TM 10-3930-675-20-1
0044 00-7
TOPHANDLER LEVELING TROUBLESHOOTING - CONTINUED
0044 00
Table 5. Error Code 268 - Tophandler Leveling Right, Short Circuit Failure Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Error Code 268 - Tophandler Leveling Right,
Short Circuit Failure - Continued
3. Disconnect connector X189
from tophandler junction box
at end of boom. Place ignition
switch to OFF position and
check continuity between
connector 6035 pin 1 and pin
2 and between connector
6035 pin 1 and pin 2 and
chassis.
a. If continuity is not present,
repair or replace connectors
(WP 0111 00).
b. If wiring harness requires
replacement,
notify
DS
Maintenance.
4. Enter DIAG ATTACH-
MENT 14 (16) menu and
check
current
of
OSCILLATION,
RIGHT
OUTPUT. Current should be
present with joystick leveling
right activated.
a. If current is not present,
replace ECU (791) (WP 0076
00).
b. If current is present, notify
SRA.
Table 6. Error Code 270 - Tophandler Leveling Left, Open Circuit Failure Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Error Code 270 - Tophandler Leveling Left,
Open Circuit Failure
1. Check wires and cables from
tophandler control valve to
boom for obvious damage.
Repair or replace damaged
connectors (WP 0111 00).
2. Disconnect
electrical
connector
6036
from
tophandler
left
leveling
solenoid.
Place
ignition
switch to ON position and
perform voltage check at pins
1 and 2.
If 20-25V is present at connector
6036, replace leveling left
solenoid (WP 0169 00).
3. Disconnect connector X189
from tophandler junction box
at end of boom. Place ignition
switch to ON position and
perform
voltage
check
between connector X189
pin G and pin H.
DIAG TOP LIFT 12(16)
OUTPUT/INPUT
SLEW CW 0mA 0mA
SLEW CCW 0mA 0mA