TM 10-3930-675-20-10044 00-6TOPHANDLER LEVELING TROUBLESHOOTING - CONTINUED0044 00Table 4. Error Code 267 - Tophandler Leveling Right, Open Circuit Failure Troubleshooting Procedures - Continued.MALFUNCTIONTEST OR INSPECTIONCORRECTIVE ACTIONError Code 267 - Tophandler Leveling Right,Open Circuit Failure - Continueda. If 20-25V is present, checkcontinuity between con-nector X189 pin E andconnector 6035 pin 1;between connector X189pin F and connector 6035pin 2; between connectorX189 pin F and ECU (791)connector 3 pin 5.a. If continuity is not present,repair or replace connectors(WP 0111 00). b. If wiring harness requiresreplacement, notify DSMaintenance.b. If voltage is not present,enter “DIAG ATTACH-MENT 14 (16)” menu andcheck current ofOSCILLATION, RIGHTOUTPUT. Current shouldbe present with joystickleveling right activated.a. If current is not present,replace ECU (791) (WP 007600).b. If current is present, notifySRA.Table 5. Error Code 268 - Tophandler Leveling Right, Short Circuit Failure Troubleshooting Procedures.MALFUNCTIONTEST OR INSPECTIONCORRECTIVE ACTIONError Code 268 - Tophandler Leveling Right,Short Circuit Failure1. Check wires and cables fromtophandler control valve toboom for obvious damage.Repair or replace damagedconnectors (WP 0111 00).2. Disconnect electricalconnector 6035 fromtophandler leveling rightsolenoid. Place ignitionswitch to ON position. Errorcode 267 will be displayed.Perform voltage check at pins1 and 2.If 20-25V is present at connector6035, replace leveling rightsolenoid (WP 0169 00).DIAG TOP LIFT 12(16)OUTPUT/INPUTSLEW CW 0mA 0mASLEW CCW 0mA 0mA