TM 10-3930-675-20-10044 00-5TOPHANDLER LEVELING TROUBLESHOOTING - CONTINUED0044 00Table 3. Error Code 240 - Tophandler Leveling Locking Control, Wiring Circuit FailureTroubleshooting Procedures - Continued.MALFUNCTIONTEST OR INSPECTIONCORRECTIVE ACTIONError Code 240 - Tophandler Leveling LockingControl, Wiring Circuit Failure - Continuedb. If voltage is not present,enter “Diag ATTACH-MENT 15 (16)” menu andcheck voltage of OSC.OUTPUT. Voltage shouldchange from 0 to 24V andvice versa if the “levelinglocked” switch is activated/deactivated.a. If voltage is not as specified,replace ECU (791) (WP 007600).b. If voltage is changing, notifySRA.Table 4. Error Code 267 - Tophandler Leveling Right, Open Circuit Failure Troubleshooting Procedures.MALFUNCTIONTEST OR INSPECTIONCORRECTIVE ACTIONError Code 267 - Tophandler Leveling Right,Open Circuit Failure1. Check wires and cables fromtophandler control valve toboom for obvious damage.Repair or replace damagedconnectors (WP 0111 00).2. Disconnect electricalconnector 6035 fromtophandler right levelingsolenoid. Place ignitionswitch to ON position andperform voltage check at pins1 and 2.If 20-25V is present at connector6035, replace right levelingsolenoid (WP 0169 00).3. Disconnect connector X189from tophandler junction boxat end of boom. Place ignitionswitch to ON position andperform voltage checkbetween connector X189pin E and pin F.DIAG TOP LIFT 12(16)OUTPUT/INPUTSLEW CW 0mA 0mASLEW CCW 0mA 0mA