TM 10-3930-675-20-2
0095 00-4
TRANSMISSION SENSORS REPLACEMENT - CONTINUED
0095 00
INSTALLATION
CAUTION
Spacers removed with sensors must be reinstalled with same sensor. If sensor is replaced, spacer must be
replaced with the same type and quantity when installing sensor. Failure to follow this caution may result in
damage to equipment or improper sensor operation.
NOTE
If reinstalling sensor, ensure new o-ring seal is used. If installing new sensor, ensure o-ring provided is
installed.
1.
Install sensor with o-ring in transmission. Tighten sensors as follows:
a.
Outspeed speed sensor: 204 lb-in (23 Nm)
b.
All other sensors: 265 lb-in (30 Nm)
NOTE
Ensure connector and sensor key are alined prior to connection.
2.
Connect electrical connector to sensor.
SENSOR
O-RING