TM 10-3930-675-20-20095 00-4TRANSMISSION SENSORS REPLACEMENT - CONTINUED0095 00INSTALLATIONCAUTIONSpacers removed with sensors must be reinstalled with same sensor. If sensor is replaced, spacer must bereplaced with the same type and quantity when installing sensor. Failure to follow this caution may result indamage to equipment or improper sensor operation.NOTEIf reinstalling sensor, ensure new o-ring seal is used. If installing new sensor, ensure o-ring provided isinstalled.1.Install sensor with o-ring in transmission. Tighten sensors as follows:a.Outspeed speed sensor: 204 lb-in (23 Nm)b.All other sensors: 265 lb-in (30 Nm)NOTEEnsure connector and sensor key are alined prior to connection.2.Connect electrical connector to sensor. SENSORO-RING