TM 10-3930-675-20-2
0094 00-3
FUEL LEVEL SENDING UNIT REPLACEMENT - CONTINUED
0094 00
INSTALLATION
NOTE
Replacement fuel level sending unit comes with a new o-ring.
1.
Install fuel level sending unit (4) with o-ring to top of fuel tank (3).
2.
Connect connector (6) of fuel level sending unit (4) to wiring harness connector (5).
3.
Secure cable (2) to frame and to fuel tank (3) with two clamps (1).
END OF WORK PACKAGE
4
3
2
1