TM 10-3930-675-20-20050 00-2Table 1. Preventive Maintenance Checks and Services(PMCS) for the RT 240 RTCH - Continued.ItemNo.IntervalMan-HoursItem ToCheck/ServiceProcedureEquipment Not Ready/Available If:2Quarterly(50 Hours or 90 Days)Transmission AOAP Oil Sampling ValveAccess remote hydraulic control com-partment and take sample of transmis-sion oil:a. Ensure transmission is at operatingtemperature.b. Remove cap from discharge port.Clean sampling valve port with rag.c. Open and close knob of valve suffi-ciently to allow approximately 2 oz(60 ml) of oil to be collected intosuitable container. Discard oil.d. Open and close knob of valve toallow sample to be collected intoclean sample bottle approximately 1/2in (1.3 cm) below neck of sample bot-tle.e. Install cap on discharge port andcheck for leaks.3Quarterly(300 Hours)Engine Oil FilterAccess engine compartment and changeengine oil filter:a. Start engine and bring to operatingtemperature (TM 10-3930-675-10).b. Shut down engine (TM 10-3930-675-10). Drain engine oil and replacefilter (LO 10-3930-675-12).WARNINGDO NOT perform fuel system checks, inspections or maintenancewhile smoking or near fire, flame or sparks. Fuel may ignite, causingdamage to vehicle and injury or death to personnel.4Quarterly(300 Hours)Engine Fuel Filter/Water Separatora. Replace fuel filter/water separator(WP 0058 00).b. Inspect fuel lines, fuel tank, and fuelsystem components for leaks anddamage. If authorized, replace dam-aged components.