TM 10-3930-675-20-20165 00-3AUXILIARY HYDRAULIC PUMP REPLACEMENT - CONTINUED0165 00REMOVAL - CONTINUED6.Remove nut (18), lockwasher (19), and disconnect strap (17) and gray wire (20). 7.Disconnect two connectors (16) from solenoid (15).8.Peel back rubber boot and remove nut (21), lockwasher (22), and disconnect power cable (23) from solenoid (15).9.Remove two bolts (27) and washers (28) from underside of pump (8) and mounting bracket (26).10.Remove two allen screws (24) from clamp (25).11.Remove pump (8) and two spacers (29) from mounting bracket (26).15161718,192021,2223824252627,2829