TROUBLESHOOTING PROCEDURES (NON-ERROR CODE) - CONTINUED
0007 00
Table 13. Solar
Charger Not Working (USMC Only)
Troubleshooting Procedures (Non-Error Code).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Solar Charger Not Working (USMC Only).
1. Inspect solar panel and wiring Replace damaged solar panel
connections for damage and (WP 0109 00).
connection.
2. Check for blown 2 amp fuse Replace blown 2 amp fuse (WP
located in the fuse holder on 0109 00).
the RED wire connected to the
master switch battery side
3. Inspect 24V Pulse module for Replace damaged/non-
damage and connection (WP functioning 24V Pulse module
0048 00-33). Blinking red (WP 0109 00).
LED on 24V Pulse module
indicates voltage is connected
and unit is operating.
END OF WORK PACKAGE