TM 10-3930-675-24-1
BOOM LIFTING/LOWERING TROUBLESHOOTING - CONTINUED
0040 00
Table 3. Error Code 151 - Lift Cylinder Locking Valve, Wiring Circuit Failure Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Error Code 151 - Lift Cylinder Locking Valve, 1. Enter "DIAG SERVO" 11(13)
Wiring Circuit Failure.
in the diagnostic menu. Should
for damage and proper connector.
have 24V when activating
boom lowering function.
2. Disconnect the connectors
a. If no voltage (24V) is found,
from 6001 and 6002 from the
lift cylinder locking valves.
valve harness.
Check voltage between the two
b. If voltage (24V) is found,
pins of each connector with the
ignition ON. Should have
DIAG SERVO
11(13)
OUTPUT/INPUT
voltage 24V during the
FAN
0mA
0mA
lowering function.
be 18 to 20 Ohms.
BL.VALVE 0.00V
0mA
c. Replace damaged or open
locking valve harness.
d. Replace locking valve (WP
0252 00).
3. Check voltage 24V at X159 a. If no voltage (24V) is found,
pin 2 with the ignition ON.
disconnect ECU (790)
connector 2 and check pin 3
00-8).
for damage and check
continuity of wire A1592 (WP
b. Repair or replace damaged
wires or connectors (WP 0113
00).
c. Replace damaged ECU (790)
(WP 0080 00).
4. Remove the engine cover to a. If no voltage (24V) at X167
access X167 and check voltage
(24V) at X167 pin 14 and 15
wires GY and BK going to
00-8).
b. If no voltage (24V) is found at
X167 pin 14, check locking
valves (6001 and 6002)
soleniod harness for damage
8).
c. Replace damaged or open
locking valve harness.
d. Notify Sustainment
Maintenance to replace
damaged or open X159 to
X167 harness.
0040 00-3