TM 10-3930-675-24-1
TOPHANDLER TILT TROUBLESHOOTING - CONTINUED
0043 00
Table 4. Error Code 261 - Tophandler Tilt OUT Control, Wiring Circuit Failure Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Error Code 261 - Tophandler Tilt OUT Control, 1. Check wires and connectors at a. Repair or replace connectors
Wiring Circuit Failure.
tophandler control valve and
(WP 0113 00).
tophandler junction box for b. Replace damaged wiring
damage.
harness (WP 0221 00).
2. Enter DIAG ATTACHMENT If no INPUT mA values display,
13(16) in the diagnostic menu. continue with troubleshooting
Activate the tilt OUT function. procedure.
3. Disconnect connector 6010 a. If no voltage (15 to 18V) is
from the tophandler tilt OUT
DIAG ATTACHMENT 13(16)
OUTPUT/INPUT
TILT IN 0mA
0mA
and check voltage (15 to 18V)
TILT OUT 0mA
0mA
between both pins of the b. If voltage (15 to 18V) is found,
connector.
solenoid. Should be 18 to 26
Ohms.
c. Replace open of faulty
d. Replace X188 to solenoids
wiring harness (WP 0221 00).
4. Disconnect connector X188 a. If no voltage (15 to 18V) is
from the tophandler junction
box. Turn the ignition ON.
wires A188AA, A188AB,
Check voltage (15 to 18V) at
the mounted part of the
connector between pins E and b. Repair or replace damaged
F.
wires or connectors (WP 0113
00).
5. Disconnect
ECU
(791) a. Repair or replace damaged
connector 3. Inspect ECU and
connector (WP 0113 00).
connector pins for damage.
b. Replace ECU (791) (WP 0077
00).
NOTE
Multiple error codes associated with a common connec-
tor on ECU (791) may be the result of a short to ground
in the harness for the common solenoid voltage. (See
WP 0005 00
for troubleshooting multiple error codes.)
0043 00-4