TM 10-3930-675-24-1
TOPHANDLER TILT TROUBLESHOOTING - CONTINUED
0043 00
Table 5. Error Code 262 - Tophandler Tilt OUT Control, Component Failure Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Error Code 262 - Tophandler Tilt OUT Control, 1. Check wires and connectors at a. Repair or replace connectors
Component Failure.
tophandler control valve and
(WP 0113 00).
tophandler junction box for b. Replace damaged wiring
damage.
harness (WP 0221 00).
CAUTION
Uncontrolled function may occur with this error code.
2. Disconnect connector 6010 Replace open or shorted solenoid
from the tophandler tilt OUT (WP 0171 00).
DIAG ATTACHMENT 13(16)
OUTPUT/INPUT
TILT IN 0mA
0mA
TILT OUT 0mA
0mA
and between each pin and
should be 18 to 26 Ohms.
3. Disconnect connector X188 Replace open or shorted/
from tophandler junction box grounded X188 to solenoids
and disconnect solenoid 6010. wiring harness (WP 0221 00).
Check for short to ground at
loose part of X188 at pin F
4. Disconnect
ECU
(791) a. Repair or replace shorted
connector 3. Inspect ECU and
wires or connectors (WP 0113
connector pins for damage.
00).
Check wire A188F (pin 4) for b. Replace ECU (791) (WP 0077
00).
27).
NOTE
Multiple error codes associated with a common connec-
tor on ECU (791) may be the result of a short to ground
in the harness for the common solenoid voltage. (See
WP 0005 00
for troubleshooting multiple error codes.)
0043 00-5