TM 10-3930-675-24-1
TOPHANDLER LEVELING TROUBLESHOOTING - CONTINUED
0044 00
Table 4. Error Code 267 - Tophandler Leveling Right, Open Circuit Failure Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Error Code 267 - Tophandler Leveling Right, 1.
Check wires and connectors at a.
Repair or
replace connectors
Open Circuit Failure.
tophandler control valve and
(WP 0113 00).
tophandler junction box for b. Replace damaged wiring
damage.
harness (WP 0221 00).
2. Enter DIAG ATTACHMENT If no INPUT mA values display,
14(16) in the diagnostic menu. continue with troubleshooting
Activate the leveling right procedure.
function.
DIAG ATTACHMENT 14(16)
3. Disconnect connector 6035 a. If no voltage (15-18V) is
OSC, RI
from
the
tophandler
OSC, LE
tophandler leveling right
and check voltage (15 to 18V) b. If voltage (15-18V) is found,
between both pins of the
connector.
solenoid. Should be 18 to 26
Ohms.
c. Replace open or faulty
d. Replace X189 to solenoids
wiring harness (WP 0221 00).
4. Disconnect connector X189 a. If no voltage (15 to 18V) is
from the tophandler junction
box. Turn the ignition ON.
wires
A188AA
through
Check voltage (15 to 18V) at
the mounted part of the
connector between pins E and b. Repair or replace damaged
F.
wires or connectors (WP 0221
00).
5. Disconnect
ECU
(791) a. Repair or replace damaged
connector 3. Inspect ECU and
connector (WP 0113 00).
connector pins for damage.
b. Replace ECU (791) (WP 0077
00).
NOTE
Multiple error codes associated with a common connec-
tor on ECU (791) may be the result of a short to ground
in the harness for the common solenoid voltage. (See
WP 0005 00
for troubleshooting multiple error codes.)
0044 00-4