0044 00
Table 5. Error Code 268 - Tophandler Leveling Right, Short Circuit Failure Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Error Code 268 - Tophandler Leveling Right, 1.
Check wires and cables from a.
Repair or
replace connectors
Short Circuit Failure.
tophandler junction box for
(WP 0113 00).
damage.
b. Replace damaged wiring
harness (WP 0221 00).
CAUTION
Uncontrolled function may occur with this error code.
2. Disconnect connector 6035 Replace open or shorted solenoid
from the tophandler leveling (WP 0171 00).
DIAG ATTACHMENT 14(16)
OSC, RI
right
solenoid.
Check
OSC, LE
between both pins and between
Ohms.
3. Disconnect connector X189 c. Replace
shorted/grounded
from the tophandler junction
X189 to solenoids wiring
box and disconnect solenoid
harness (WP 0221 00).
6035. Check for short to
ground at loose part of X189 at
00-27).
4. Disconnect
ECU
(791) a. Repair or replace shorted
connector 3. Inspect ECU and
wires or connectors (WP 0113
connector pins for damage.
00).
Check wire A189F (pin 5) for b. Replace ECU (791) (WP 0077
00).
27).
NOTE
Multiple error codes associated with a common connec-
tor on ECU (791) may be the result of a short to ground
in the harness for the common solenoid voltage. (See
WP 0005 00
for troubleshooting multiple error codes.)