TM 10-3930-675-24-2
WATER PUMP REPLACEMENT - CONTINUED
0068 00
INSTALLATION
NOTE
Water pump must be rotated outward from the top until transfer outlet clears thermostat housing
support during installation.
1.
Install new seal (14) on water pump (10) and install water pump.
2.
Install new seal (13) on transfer connection (12) and install transfer connection into water pump (10).
3.
Rotate water pump (10) inward and install three water pump mounting screws (15). Tighten screws to 35 lb-ft (47 Nm).
4.
Install new gasket (11) on water pump transfer connection (12).
5.
Position transfer connection (12) and secure in place with two screws (9). Tighten screws to 18 lb-ft (24 Nm).
9
10
15
11
12
14
13
NOTE
Oil seal must be installed with lip of seal and shaft clean and dry. Yellow lip of seal must face out.
6.
Install new gasket (5) and new oil seal (6).
0068 00-4