TM 10-3930-675-24-2
FORDING WATER LEVEL SENSOR REPLACEMENT
THIS WORK PACKAGE COVERS
Removal, Installation
INITIAL SETUP
Maintenance Level
Materials/Parts
Organizational
Nut, lock (P/N 920076.002) (2)
Tools and Special Tools
Equipment Condition
Tool Kit, General Mechanic's (Item 128, WP 0289
Master battery switch in OFF position
REMOVAL
1.
Disconnect sensor connector (9) from wiring harness sensor (10).
2.
Remove screw (5), washer (6), and clamp (7) from fan shroud (8) and sensor cable (11).
3.
Remove two locknuts (2), washers (3), and screws (4), and remove clamp (1) and sensor (12) from fan shroud (8). Dis-
card locknuts.
7
8
2,3,4
5,6
10
9
1
12
FORWARD
11