TM 10-3930-675-24-2
ELECTRICAL GENERAL MAINTENANCE INSTRUCTIONS - CONTINUED
0113 00
WATERPROOF CONNECTOR REPAIR - CONTINUED
7.
Insert metal strands (23) of wire (22) fully into rear of pin (24).
8.
Using crimping tool, securely crimp pin (24) to metal strands (23) of wire (22).
9.
Push pin (24) into rear of connector (25) until fully seated.
10.
Install seal (21) on rear of connector (25).
11.
Install gasket (26) and end cover (27) on front of connector (25).
21
25
26
22
23
24
27
MILITARY CONNECTOR REPAIR
1.
Slide shell (28) back on wire (29) to expose sleeve (32).
2.
Remove sleeve (32) from terminal (31) by pulling sleeve forward.
3.
If defective, remove terminal (31) from wire (29) by cutting through wire just behind terminal.
32
31
28
29
30
4.
Using wire stripping tool, strip insulation off wire (29) to expose length of metal strands (30) equal to depth of terminal
(31).
5.
Using crimping tool, securely crimp terminal (31) to metal strands (30) of wire (29).
6.
Install sleeve (32) on terminal (31) by pushing sleeve over front of terminal until fully seated.
7.
Slide shell (28) up wire (29) and over sleeve (32).
RING TERMINAL REPAIR
1.
Remove ring terminal (38) from wire (34) by cutting through wire just behind heat shrink tubing (33).
0113 00-6