INSTALLATION
1.
Position two new rubber seals (3) and sight gage (4) on side of hydraulic reservoir (5).
2.
Install two new O-rings (2) and fluid passage bolts (1) on sight gage (4).
1,2,3
4
5
3.
Fully lower boom and check for leaks (TM 10-3930-675-10).