TM 5-3810-306-34
TABLE 3-1. DIRECT AND GENERAL SUPPORT TROUBLESHOOTING (CONTD)
Malfunction
Test or Inspection
Corrective Action
36. STICKING OUTRIGGER CONTROL VALVE
Step 1.
Distortion caused by tie bol ts being overtorqued.
If OK, do Step 2.
b. Retorque tie bolts.
Step 2.
Flow in excess of valve rating.
a. Install flow meter in exhaust line of pump. Under
moderate load check for proper output (27 GPM at
2400 rpm).
Step 3.
Pressure in excess of valve rating.
a. Check relief valve setting with that recommended.
(Refer to TM 5-3810-306-20.) If OK, do Step 4.
Step 4.
Electrical failure.
37. EXTERNAL LEAKAGE AT CONTROL VALVE
Step 1.
Damage preformed packings or quad rings.
a. Inspect for chipped packings and replace. (Refer to
Step 2.
Loose tie bolts.
Step 3.
Step 3.
3-28