TM 5-3810-306-34
TABLE 3-1. DIRECT AND GENERAL SUPPORT TROUBLESHOOTING (CONTD)
Malfunction
Test or Inspection
Corrective Action
38. OUTRIGGER CONTROL VALVE SOLENOID FAILURE
Step 1.
No current.
a. Check power source of at least 85% of coil rating.
If OK, do Step 2.
Step 2.
a. Check solenoid for obvious damage. If OK, do Step 3.
Step 3.
Short in solenoid.
a. Check solenoid.
3-29