TM 55-8145-201-14
1-4. CORROSION PREVENTION AND CONTROL - cont.
b.
While corrosion is typically associated with rusting of metals, it can also include deterioration of other
materials, such as rubber and plastic. Unusual cracking, softening, swelling or breaking of the materials may
be a corrosion problem.
c.
If a corrosion problem is identify, it can be reported using Standard Form 368, Product Quality Deficiency
Report Using key words such as "rust", "deterioration", or "cracking" will insure that the information is
identified as a CPC problem. The form should be submitted to the address specified in DA Pam 738-750.
1-5. REPORTING EQUIPMENT I MPROVEMENT RECOMMENDATIONS (EIRs).
If your container needs improvement, let us know. Send us an EIR. You, the user, are the only one who can tell us what
you don't like about your equipment. Put it on an SF 368 (Quality Deficiency Report). Mail it to us at :Commander, U.S.
Army Troop Support Command, ATTN: AMSTR-MOF, 4300 Goodfellow Boulevard, St. Louis, MO 63120-1798. We'll
send you a reply.
1-6. NOMENCLATURE CROSS REFERENCE LIST .
Common Name
Official Nomenclature
Container
Container, Refrigerated, Model SC-219
1-7. LIST OF ABBREVIATIONS.
Abbreviation
Nomenclature
F
Degrees Fahrenheit
Hz
Hertz
1-8. GLOSSARY.
Term
Description
Stylus
A point used to mark or write on paper. The
temperature recorder stylus marks the
paper chart to record the temperature
changes inside the container.
1-2