TM 55-8145-201-14
Table 2-1. Operator Preventive Maintenance Checks and Services for Model SC-219 - cont.
Location
Item
Interval
Item to
Procedure
Not Fully Mission
No.
Check/Service
Capable If:
6
Before
Roof Panel
a. Inspect for obvious damage,
Roof panel split, cracked or
cracks, splits or delamination.
punctured through to
interior.
b. Check for loose or missing
fasteners.
c. Inspect container upper side
Container frame cracked.
frame for cracks, splits, and
broken welds.
7
Before
Refrigeration
a. Check for loose or missing bolts
Mounting bolts missing.
Unit
securing refrigeration unit to
container.
b. Perform Before PMCS on
refrigeration unit (TM 9-4110-
252-14).
8
Before
Generator Set
a. Check for loose or missing bolts
Mounting bolts missing.
securing generator set to
container.
b. Perform Before PMCS on
12/34
9
Before
Electrical Cables
a. Inspect for cuts, deep abrasions,
Cables cut or burned.
and burned or discolored wiring.
b. Check that cable connections to
set are secure.
10
Before
Fuel Tank
a. Check fuel level in tank. If low,
remove filler cap and add fuel as
required.
b. Inspect fuel tank, lines, and
Fuel tank leaks.
connections for leaks.
c. Inspect fuel tank gage for
damaged or missing indicator.
2-10