TM 55-8145-202-14
4-20.
CABLE, ELECTRIC POWER (GEN SET)
This task covers:
a. Removal
b. Disassembly
c. Cleaning
d. Inspection
e. Repair
f. Assembly
INITIAL SET-UP:
Tools:
General Mechanics Tool Kit (Item 1, App B)
Electrical Repair Kit (Item 2, App B)
Equipment Condition:
Materials/Parts:
Refrigeration unit shutdown (TM 9-4110-258-13)
Generator set shutdown (TM 5-6115-585-12/34)
a.
Removal.
(2) Tag and disconnect cable wires at terminal box on generator set (TM 5-6115-585-12)
b.
Disassembly.
(1) Remove two screws (1) and cord clamps (2) from gland cap (3).
(2) Remove two screws (4) and gland cap (3) from housing (5).
(3) Loosen self-tapping screws (6), to release terminal block (7) from housing (5).
(4) Pull the terminal block with wiring (8) from the housing (5). Loosen the four terminal screws (9). Tag
disconnected wiring (8).
(5) Pull terminal block (7) from housing and gland (11), and slide the housing (4) off the cable (10).
4-21