TM 55-8145-202-14
4-29.
REFRIGERATION UNIT - Continued
3)
Loosen two screws (3) and open junction box cover (4) located in the refrigeration unit. Access through
left hand panel.
(4) Tag and disconnect wires (5) by loosening terminal screws (6).
(5) Store power cable inside refrigeration unit (TM 9-4110-258-13).
(6) Position tines (7) of forklift under refrigeration unit (8).