TM 9-3950-253-13&P
0070
STOWAGE GUIDE SENSOR HARNESS INSTALLATION
1.
Install 13 clamps (Figure 19, Item 4), bolts (Figure 19, Item 3), and nuts (Figure 19, Item 2) on stowage
assembly (Figure 19, Item 1).
2.
Underneath stowage assembly (Figure 19, Item 1), install new tiedown straps (Figure 19, Item 5) as
necessary to secure wiring harnesses to stowage assembly.
Figure 19. Clamp and Tiedown Strap Installation.
NOTE
Perform steps 3 through 5 for both right and left sides.
3.
Connect stowage angle sensor harness (Figure 20, Item 7) to stowage angle sensor (Figure 20, Item 1).
4.
Install stowage guide sensor harness (Figure 20, Item 3), two cable clamp caps (Figure 20, Item 6), and four
bolts (Figure 20, Item 5) on stowage guide (Figure 20, Item 4).
5.
Connect stowage guide sensor harness (Figure 20, Item 3) to stowage guide sensor (Figure 20, Item 2).
03/15/2011Rel(1.10)root(maintwp)wpno(M582069)