TM 10-3930-641-20
ORGANIZATIONAL PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) (CONT)
(Sheet 29 of 30)
LOCATION
ITEM TO
ITEM
CHECK/
NOT FULLY MISSION
NO.
INTERVAL
MAN-HOURS
PROCEDURE
CAPABLE IF:
SERVICE
NOTE
2,000 Hours or 1.0 Hours
Hydraulic Sys-
43
(CONT) Annual
tem
Do not start engine.
m.Turn power switch to ON position. LOW HYD
OIL indicator should come on.
n. With power switch still on, begin filling hydrau-
lic tank with oil (Item 7, 7.1, or 8, Appendix C).
o. LOW HYD OIL indicator should turn off when
oil level goes above ADD COLD mark in sight
gage.
p. Turn power switch to OFF position.
q. Continue to add oil until level is at FULL COLD
mark or completely fills sight gage.
r. Install filler cap.
s. Start engine, raise container handler forks, and
tilt them back and forth several times. (See TM
10-3930-641-10.)
t. Lower container handler forks to the ground and
apply parking brake. (See TM 10-3930-641-10.)
u. Oil must be free of bubbles. If bubbles are
present, inspect suction lines hoses and clamps.
v. Shut down engine. (See TM 10-3930-641-10.)
Go on to Sheet 30
Change 2
2-24.10