TM 10-3930-641-20
ELECTRICAL SYSTEMS TROUBLESHOOTING (CONT)
(Sheet 1 of 2)
PROBLEM NO. 24
CONTAINER LOCK LIGHTS DO NOT WORK
INDICATOR LIGHTS (CONTAINER
LOCK INSTRUMENT PANEL, CLIP)
POWER switch ON.
NOTE A: The container lock light panel lights receive their power from fuse 5 in LHIP. This same fuse powers the dome light circuit, therefore, if the
dome light works the fuse and wiring to the BLACK connector at RH side of cab are good. Problem is either in CLIP or wiring from
BLACK connector to CLIP.
NOTE B: If only one lamp does not light when lens is pressed, problem is in bulb, socket or related wiring within panel.
NOTE C: If only one lamp does not light when in normal operation (see OPERATOR'S CONTROLS AND INDICATORS), problem is either in limit
switch on container handler or in associated wiring. See TM 10-3930-641-10.
CONTAINER LOCK INDICATOR CIRCUIT (See Sheet 2)
Go on to Sheet 2