TM 10-3930-641-20
ELECTRICAL SYSTEMS TROUBLESHOOTING (CONT)
(Sheet 2 of 7)
PROBLEM NO. 25 (CONT)
ANSWER
YES
NO
REMARKS
STEP
QUESTION OR INSTRUCTION
Make sure DK G wire harness connector behind LHIP is com-
pletely connected.
3
2
1
Check fuse (NOTES E and F). Is fuse good?
--
--
If new fuse blows, go to Step 3.
Replace fuse (use 10 amp fuse only).
2
5
4
Gain access to rear of LHIP. Is voltage present (NOTE B) at
3
switch terminal where PR wire connects?
Repair/replace 16 gage PR wire from fuseholder to switch.
4
NOTE G.
Is voltage present at other wire on switch when switch is turned 7
6
5
ON?
Turn POWER switch OFF. Replace switch.
6
Go on to Sheet 3