ALTERNATOR SPECIFICATIONS
(Sheet 1 of 1)
24V Delco Remy Number 1117248
Polarity is negative ground.
Speed for testing ................................................................................. 5000
Rotation can be either direction.
Output when cold:
Fasten carbon pile to battery to get maximum output ............. 54A
Rated output, hot .................................................................................. 50A
Field current at 24V and 800F (270C) ...................................... 2.5 to 2.9 A
Voltage regulator:
Voltage setting range..................................................... 26 to 30 V
Adjust voltage setting to ......................................................... 28 V
Then increase speed to get maximum output ......................... 50A
(1)
pulley ................................................ 75 _ 5 lb. ft. (102 7 N.m)
TA098827
(2)
Torque for output terminal ............... 10 + 1 lb. ft. (14 1.4 N.m)
Torque for bolts holding bottom
of alternator to bracket .................................... 24 + 3 lb. ft. (33 4 N.m)
to adjust strap ................................................ 56 7 lb. ft. (76 10 N.m)