TM 10-3930-641-34-1
TRANSMISSION PRESSURE CONTROL VALVE SPECIFICATIONS (CONT)
(Sheet 2 of 2)
(6)
6P4978 Spring for converter inlet valve:
Length under test force ........................................... 1.069 in (27.15 mm)
Test force ......................................................... 15.1 + .76 lb (67 * 3.4 N)
Free length after test ............................................... 1.500 in (38.10 mm)
Outside diameter ..................................................................... 969 in (24.61 mm)
(7)
6P9783 Spring (inner) (yellow stripe):
Length under test force ........................................... 2.220 in (56.39 mm)
Test force ................................................................ 13.9 i .7 lb (62 i 3 N)
Free length after test ............................................... 3.488 in (88.60 mm)
Outside diameter ........................................................ 434 in (11.02 mm)
(8)
6P9784 Spring (outer) (yellow stripe):
Length under test force ........................................... 2.220 in (56.39 mm)
Test force ....................................................... 29.3 i 1.46 lb (131 i 6.5 N)
Free length after test ............................................... 3.488 in (88.60 mm)
Outside diameter ........................................................ 640 in (16.26 mm)
(9)
Torque for bolts (three)........................................ 22 3 lb ft (30 i 4 N m)
Section AA 7S4607 Detent Assembly (four):
(A) Maximum free length ..................................... 1.215 in (30.86 mm)
(B) A force of 7.2 i .7 lb................................................. (32 i 3 N) must
hold the ball at ............................................... 1.180 in (29.97 mm)
(C) A force of 10.1 i 1.0 lb............................................(45 + 4 N) must
hold the ball at ............................................... 1.090 in (27.69 mm)
TA098877
End
2-147