TM10-3930-641-34-2
SEQUENCE VALVE TEST
(Sheet 1 of 4)
This task covers: Test for sequence and control valve.
INITIAL SETUP
Test Equipment
Materials/Parts
Troubleshooting Reference
Two 0-600 psi (0-42.2 Kg/cm2) pressure gages
None
Pages 2-47, 2-48
Needle valve
Hydraulic lines and fittings
Equipment Condition
Transmission oil supply at 400 psi (28.1 Kg/cm2)
Sequence valve removed from vehicle.
Fabricated plate (see Sheet 2)
Special Tools
Personnel Required
None
One mechanic
References
General Safety Instructions
Sequence and pressure control valve
Test in a clean area.
Go on to Sheet 2
4-237