TM 10-3930-675-10-1
PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - CONTINUED
0013 00
Table 1. Preventive Maintenance Checks and
Services (PMCS) for RTCH-RT 240 - Continued.
LOCATION
ITEM TO
ITEM
CHECK/
NOT FULLY MISSION
NO.
INTERVAL
SERVICE
PROCEDURE
CAPABLE IF:
NOTE
15
Before
Engine Oil
Level
To ensure an accurate reading, RTCH must be parked on level
ground.
Check engine oil level on dipstick. Main-
tain oil level within crosshatched area at
end of dipstick. If level is low, add oil IAW
ENGINE
OIL FILL
ENGINE
OIL
LEVEL
GAGE
CROSS
HATCHED AREA
350-040A
16
Before
Battery
Open battery storage compartment and Damage or missing parts that
Storage Com- visually check batteries, battery cables, would impair operation is evi-
partment
equipped), and master battery switch for
damage.
NOTE
Perform the following checks if forklift kit is to be used.
17
Before
a. Ensure all retaining and locking pins are Retaining or locking pins are
present and properly secured.
missing.
b. Inspect hydraulic hoses and quick-dis- Hydraulic hoses or quick-
connects for dirt, damage, and proper disconnects are damaged.
operation.
0013 00-5