TM 10-3930-675-10-2
PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - CONTINUED
0013 00
Table 1. Preventive Maintenance Checks and
Services (PMCS) for RTCH-RT 240V2 - Continued.
LOCATION
ITEM TO
ITEM
CHECK/
NOT FULLY MISSION
NO.
INTERVAL
SERVICE
PROCEDURE
CAPABLE IF:
LIFTING
BOOM AND
TOP-
HANDLER
10
Before
Boom
Check all hydraulic cylinders, hoses,
Class III leaks are evident.
lines, and fittings for damage and leaks.
11
Before
Boom Lights
Check all light assemblies for damage or
a. Damage to lights that would
missing parts.
impair night operation.
b. Twistlock indicator lights are
damaged.
12
Before
Tophandler
Check all hydraulic cylinders, hoses,
Class III leaks are evident.
lines, and fittings for damage and leaks.
13
Before
Tophandler
Check all light assemblies for damage or
Damage to work lights that
Lights
missing parts.
would impair night operation.
a. Damage that would impair
14
Before
Twistlocks
Visually check all twistlocks, hydraulic
operation is evident.
cylinders, electrical wiring, and switches
for signs of damage.
b. Class III leaks are evident.
COVER
SWITCH
TWIST-
LOCK
TWIST-
LOCK
HYDRAULIC CYLINDER
HYDRAULIC LINES
350-044
0013 00-4