TM 10-3930-675-10-2
PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - CONTINUED
0013 00
Table 1. Preventive Maintenance Checks and
Services (PMCS) for RTCH-RT 240V2 - Continued.
LOCATION
ITEM TO
ITEM
CHECK/
NOT FULLY MISSION
NO.
INTERVAL
SERVICE
PROCEDURE
CAPABLE IF:
48
Weekly
Drive Belts
a. Check for loose, missing, broken, Belt is loose or damaged.
b. Check for loose, missing, broken, Belts are loose or damaged.
frayed, or cracked air conditioner drive
belts.
AIR CONDITIONER
WATER PUMP DRIVE BELT
DRIVE BELTS
49
Weekly
Fuel/Water
Separator
WARNING
DO NOT perform fuel system checks, inspections, or maintenance
while smoking or near fire, flames, or sparks. Fuel may ignite,
causing damage to machine and injury or death to personnel.
NOTE
Ensure that a suitable container is used to catch draining fluid.
a. Turn drain knob counterclockwise and
drain all water from fuel/water separa-
tor.
b. Turn knob clockwise to close.
0013 00-16