TM 10-3930-675-10-2
PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - CONTINUED
0013 00
Table 1. Preventive Maintenance Checks and
Services (PMCS) for RTCH-RT 240V2 - Continued.
LOCATION
ITEM TO
ITEM
CHECK/
NOT FULLY MISSION
NO.
INTERVAL
SERVICE
PROCEDURE
CAPABLE IF:
42
After
Boom Lights
Check all light assemblies for damage or
Damage to lights that would
missing parts.
impair night operation is
evident. Twistlock indicator
lights are damaged.
43
After
Tophandler
a. Check hydraulic cylinders for damage Class III leaks are evident.
and leaks.
b. Check hydraulic hoses, lines, and fit- Class III leaks are evident.
tings for damage and leaks.
44
After
Tophandler
Check all light assemblies for damage or
Damage to work lights that
Lights
missing parts.
would impair night operation is
evident.
a. Damage that would impair
45
After
Twistlocks
Visually check all twistlocks, hydraulic
cylinders, electrical wiring, and switches
operation is evident.
for signs of damage.
b. Class III leaks are evident.
COVER
SWITCH
TWIST-
LOCK
TWIST-
HYDRAULIC CYLINDER
HYDRAULIC LINES
LOCK
350-044
0013 00-14