TM 10-3930-675-10-2
PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - CONTINUED
0013 00
Table 1. Preventive Maintenance Checks and
Services (PMCS) for RTCH-RT 240V2 - Continued.
LOCATION
ITEM TO
ITEM
CHECK/
NOT FULLY MISSION
NO.
INTERVAL
SERVICE
PROCEDURE
CAPABLE IF:
51
Weekly
Batteries
c. Check for damaged terminal posts.
Damage is noted.
(Con't)
(USMC)
d. Check for rust, corrosion, and cleanli-
ness.
RETAINING RINGS
ELECTRICAL
CONNECTION
BATTERY
(HIDDEN)
COMPARTMENT
COVER
RETAINING RINGS
374M-0042
52
Weekly
Batteries
a. Remove battery compartment cover. Damage noted.
Check battery compartment for dam-
(RESET)
aged or missing batteries.
b. Check for damaged or missing battery Damage is noted.
filler cap.
c. Check level of distilled water in bat- Fluid level is low.
tery cells. Fluid level should be to bot-
tom of split ring.
d. Check for missing, broken, split, or Battery cables are damaged.
frayed cables.
e. Check for damaged terminal posts.
Damaged is noted.
f. Check for rust, corrosion, and cleanli-
ness.
0013 00-19