TM 10-3930-675-20-10042 00-4TOPHANDLER SLEWING TROUBLESHOOTING - CONTINUED0042 00Table 2. Error Code 130 - Overload Protection System Failure Troubleshooting Procedures.MALFUNCTIONTEST OR INSPECTIONCORRECTIVE ACTIONError Code 130 - Overload Protection SystemFailureOverload protection systemfailure occurs due to an earlierfailure (error codes 131-136) onany component related to theoverload protection system.Hydraulic speeds are limited andthe error code will flash on thedisplay every 5 seconds. Perform troubleshootingprocedures for the original errorcode (error codes 131-136).Table 3. Error Code 255 - Tophandler Clockwise Slewing, Wiring Circuit Failure Troubleshooting Procedures.MALFUNCTIONTEST OR INSPECTIONCORRECTIVE ACTIONError Code 255 - Tophandler ClockwiseSlewing, Wiring Circuit Failure1. Check wires and cables fromtophandler control valve toboom for obvious damage.Repair or replace damaged wires(WP 0111 00).2. Disconnect electricalconnector 6008 fromtophandler clockwise slewingsolenoid. Place ignitionswitch to ON position andperform voltage check.If 20-25V is present at connector6008, replace clockwise slewingsolenoid (WP 0169 00).3. Disconnect connector X188from tophandler junction boxat end of boom. Place ignitionswitch to ON position andperform voltage check atconnector X188 pin A and pinB.If voltage is not present, repair orreplace connectors (WP 011100).a. If 20-25V is present, checkcontinuity between con-nector X188 pin A andconnector 6008 pin 1;between connector X188pin B and connector 6008pin 2; and betweenconnector X188 pin B andECU (791) connector 3 pin3.a. If continuity is not present,repair or replace connectors(WP 0111 00).b. If wiring harness requiresreplacement, notify DSMaintenance.DIAG TOP LIFT 12(16)OUTPUT/INPUTSLEW CW 0mA 0mASLEW CCW 0mA 0mA
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business