TM 10-3930-675-20-10042 00-7TOPHANDLER SLEWING TROUBLESHOOTING - CONTINUED0042 00Table 5. Error Code 258 - Tophandler Counterclockwise Slewing, Wiring Circuit FailureTroubleshooting Procedures - Continued.MALFUNCTIONTEST OR INSPECTIONCORRECTIVE ACTIONError Code 258 - Tophandler CounterclockwiseSlewing, Wiring Circuit Failure - Continuedb. If voltage is not present,enter “DIAG ATTACH-MENT 12 (16)” menu andcheck current of SLEWCCW OUTPUT. Currentshould be present withjoystick activated to slewcounterclockwise.a. If current is not present,replace ECU (791) (WP 007600).b. If current is present, notifySRA.Table 6. Error Code 259 - Tophandler Counterclockwise Slewing, Component Failure Troubleshooting Procedures.MALFUNCTIONTEST OR INSPECTIONCORRECTIVE ACTIONError Code 259 - Tophandler CounterclockwiseSlewing, Component Failure1. Check wires and cables fromtophandler control valve toboom for obvious damage.Repair or replace damaged wires(WP 0111 00).2. Disconnect electricalconnector 6009 fromtophandler counterclockwiseslewing solenoid. Placeignition switch to ONposition. Error code 258 willbe displayed. Perform voltagecheck.If 20-25V is present at connector6009, replace counterclockwiseslewing solenoid (WP 0169 00).3. Disconnect connector X188from tophandler junction boxat end of boom. Place ignitionswitch to OFF position andcheck continuity betweenconnector 6009 pin 1 and pin2 and between connector6009 pin 1 and pin 2 andchassis.a. If continuity is not present,repair or replace connectors(WP 0111 00). b. If wiring harness requiresreplacement, notify DSMaintenance.DIAG TOP LIFT 12(16)OUTPUT/INPUTSLEW CW 0mA 0mASLEW CCW 0mA 0mA