TM 10-3930-675-20-1
0042 00-7
TOPHANDLER SLEWING TROUBLESHOOTING - CONTINUED
0042 00
Table 5. Error Code 258 - Tophandler Counterclockwise Slewing, Wiring Circuit Failure
Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Error Code 258 - Tophandler Counterclockwise
Slewing, Wiring Circuit Failure - Continued
b. If voltage is not present,
enter DIAG ATTACH-
MENT 12 (16) menu and
check current of SLEW
CCW OUTPUT. Current
should be present with
joystick activated to slew
counterclockwise.
a. If current is not present,
replace ECU (791) (WP 0076
00).
b. If current is present, notify
SRA.
Table 6. Error Code 259 - Tophandler Counterclockwise Slewing, Component Failure Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Error Code 259 - Tophandler Counterclockwise
Slewing, Component Failure
1. Check wires and cables from
tophandler control valve to
boom for obvious damage.
Repair or replace damaged wires
(WP 0111 00).
2. Disconnect
electrical
connector
6009
from
tophandler counterclockwise
slewing
solenoid.
Place
ignition
switch
to
ON
position. Error code 258 will
be displayed. Perform voltage
check.
If 20-25V is present at connector
6009, replace counterclockwise
slewing solenoid (WP 0169 00).
3. Disconnect connector X188
from tophandler junction box
at end of boom. Place ignition
switch to OFF position and
check continuity between
connector 6009 pin 1 and pin
2 and between connector
6009 pin 1 and pin 2 and
chassis.
a. If continuity is not present,
repair or replace connectors
(WP 0111 00).
b. If wiring harness requires
replacement,
notify
DS
Maintenance.
DIAG TOP LIFT 12(16)
OUTPUT/INPUT
SLEW CW 0mA 0mA
SLEW CCW 0mA 0mA